Power Supply Sizing (Load Profile)
Determine rated supply tier, input power, and buffer capacitor from steady/peak current and load profile (resistive / capacitive / inductive / pulse).
Key points
Power Supply Sizing (Load Profile): Determine rated supply tier, input power, and buffer capacitor from steady/peak current and load profile (resistive / capacitive / inductive / pulse). Formula: P = max(U·I_pk, U·I_load·(1+margin)) | I_in = P/(η·U_in·cosφ) | C ≥ ΔI·t_pk/ΔV. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Sizing order: steady / peak current → power basis (with margin) → round to a standard tier → check overload curve and input side. A 24V DIN-rail supply derates per its datasheet curve at 50–60°C ambient; when paralleling units, choose models with current sharing (droop / active).
Inputs
P = max(U·I_pk, U·I_load·(1+margin)) | I_in = P/(η·U_in·cosφ) | C ≥ ΔI·t_pk/ΔVCalculation model (updates with parameters)
| steady power P_load | 60 W | U_o × I_load = 24 × 2.50 |
| peak power P_pk | 144 W | U_o × I_pk |
| sizing power basis | 144 W | dominated by peak current |
| Recommended supply tier | 6.0 A | 24 V × 6.0 A ≈ 144 W tier |
| actual steady margin | 140% | for steady current; peak coverage via the overload curve |
| Input power P_in | 163.6 W | sizing basis / η=88% |
| input apparent power / current | 181.8 VA / 826.4 mA | basis for upstream breaker & input wire |
| Pulse buffer capacitor C ≥ | — | Only needed for pulse loads |
Engineering notes
- Sizing order: steady / peak current → power basis (with margin) → round to a standard tier → check overload curve and input side.
- A 24V DIN-rail supply derates per its datasheet curve at 50–60°C ambient; when paralleling units, choose models with current sharing (droop / active).
- Larger buffer capacitance lengthens inrush: verify the supply’s allowed attached capacitance for capacitive loads.
FAQ
- What is Power Supply Sizing (Load Profile) for?
- Determine rated supply tier, input power, and buffer capacitor from steady/peak current and load profile (resistive / capacitive / inductive / pulse).
- What is the formula for Power Supply Sizing (Load Profile)?
- Core formula: P = max(U·I_pk, U·I_load·(1+margin)) | I_in = P/(η·U_in·cosφ) | C ≥ ΔI·t_pk/ΔV. The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using Power Supply Sizing (Load Profile)?
- Sizing order: steady / peak current → power basis (with margin) → round to a standard tier → check overload curve and input side. A 24V DIN-rail supply derates per its datasheet curve at 50–60°C ambient; when paralleling units, choose models with current sharing (droop / active). Larger buffer capacitance lengthens inrush: verify the supply’s allowed attached capacitance for capacitive loads.
Embed this calculator on your site / blog / intranet
Copy the snippet below into any HTML-capable page — visitors get the same live calculator, styling included.