Sense-Resistor Current Measurement

Favoriteused 8 times

Voltage drop, amplified output, and dissipation of a low-side sense resistor, with an ADC range check.

Key points

Sense-Resistor Current Measurement: Voltage drop, amplified output, and dissipation of a low-side sense resistor, with an ADC range check. Formula: Vsh = I × Rsh | Vout = Vsh × G. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Kelvin four-wire connection: the sense traces must land directly on the resistor pads, not share the high-current trace.

Inputs

Vsh = I × Rsh | Vout = Vsh × G

Calculation model (updates with parameters)

INRsh100 mV−+×GADC5 V
Sense voltage Vsh100 mV
Amplified output Vout5 V
Rsh dissipation200 mW
detection resolution reference16.11 µA
⚠ Amplified output exceeds ADC full scale: reduce gain or Rsh.

Engineering notes

  • Kelvin four-wire connection: the sense traces must land directly on the resistor pads, not share the high-current trace.

FAQ

What is Sense-Resistor Current Measurement for?
Voltage drop, amplified output, and dissipation of a low-side sense resistor, with an ADC range check.
What is the formula for Sense-Resistor Current Measurement?
Core formula: Vsh = I × Rsh | Vout = Vsh × G. The tool returns results instantly using this formula and the selected parameters.
What engineering notes should I keep in mind when using Sense-Resistor Current Measurement?
Kelvin four-wire connection: the sense traces must land directly on the resistor pads, not share the high-current trace.