PCB Planar Transformer Designer

Favoriteused 16 times

Planar transformer design: turns from the volt-second equation, rounded ratio, flux check, winding width/layers, and copper loss.

Key points

PCB Planar Transformer Designer: Planar transformer design: turns from the volt-second equation, rounded ratio, flux check, winding width/layers, and copper loss. Formula: N1 ≥ Vin·D/(k_vs·f·B·Ae)|n = N2/N1 = Vout/(k_v·Vin·D). Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Take Ae from the chosen core vendor’s datasheet (E22/E32/E38/E43/E58/E64 planar E cores are common). Interleaving P/S layers significantly lowers leakage (leakage ∝ layers²); parallel multiple secondary layers for high current.

Inputs

N1 ≥ Vin·D/(k_vs·f·B·Ae)|n = N2/N1 = Vout/(k_v·Vin·D)

Calculation model (updates with parameters)

Upper core half (E planar core)PSPSPPrimary windingSecondary windingN1 = 9N2 = 5Ae (center post)Bpk = 92 mT
required ratio N2/N10.556
rounded turns N1 : N29 : 5
actual output voltage12.00 V
Operating flux density Bpk92.3 mT
Primary RMS current / suggested width0.61 A / 1.8 mm
Secondary RMS current / suggested width1.01 A / 2.9 mm
Total winding layers6 layers
Winding copper loss estimate99.22 mW

Engineering notes

  • Take Ae from the chosen core vendor’s datasheet (E22/E32/E38/E43/E58/E64 planar E cores are common).
  • Interleaving P/S layers significantly lowers leakage (leakage ∝ layers²); parallel multiple secondary layers for high current.
  • Operating flux density is set by core loss (temperature rise), not saturation: use 0.1–0.15T at 100kHz, drop below 0.05T at 500kHz.
  • Copper loss is a DC estimate (skin effect ignored): above 200kHz keep copper ≤ 2× skin depth (≈0.21mm at 100kHz; 1oz is fine).

FAQ

What is PCB Planar Transformer Designer for?
Planar transformer design: turns from the volt-second equation, rounded ratio, flux check, winding width/layers, and copper loss.
What is the formula for PCB Planar Transformer Designer?
Core formula: N1 ≥ Vin·D/(k_vs·f·B·Ae)|n = N2/N1 = Vout/(k_v·Vin·D). The tool returns results instantly using this formula and the selected parameters.
What engineering notes should I keep in mind when using PCB Planar Transformer Designer?
Take Ae from the chosen core vendor’s datasheet (E22/E32/E38/E43/E58/E64 planar E cores are common). Interleaving P/S layers significantly lowers leakage (leakage ∝ layers²); parallel multiple secondary layers for high current. Operating flux density is set by core loss (temperature rise), not saturation: use 0.1–0.15T at 100kHz, drop below 0.05T at 500kHz. Copper loss is a DC estimate (skin effect ignored): above 200kHz keep copper ≤ 2× skin depth (≈0.21mm at 100kHz; 1oz is…