Motor Sizing (Load Torque)
Size AC induction, DC, or brushed/brushless motors by load profile (constant torque / power / quadratic / shock): power, standard tier rounding, torque and overload check.
Key points
Motor Sizing (Load Torque): Size AC induction, DC, or brushed/brushless motors by load profile (constant torque / power / quadratic / shock): power, standard tier rounding, torque and overload check. Formula: P_L = T_L·n_L/9550 | P_N ≥ K·P_L/η_t | T_N = 9550·P_N/n_N | peak ≤ λ·T_N. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Four sizing steps: compute load power → apply the service factor → round to a standard power tier → check rated torque and peak overload. Select breakers / contactors / thermal relays by rated current; set the thermal relay to 1.05–1.1× I_N.
Inputs
P_L = T_L·n_L/9550 | P_N ≥ K·P_L/η_t | T_N = 9550·P_N/n_N | peak ≤ λ·T_NCalculation model (updates with parameters)
| Load shaft power P_L | 7.539 kW | T_L × n_L / 9550 |
| Required power (K×P_L/η_t) | 9.834 kW | K=1.20,η_t=92% |
| Selected rated power P_N | 11 kW | rounded to the GB series, margin 12% |
| Suggested rated speed / poles | 4 poles (rated ≈1440 r/min) | Typical rated speed of a 50Hz induction motor |
| Rated torque T_N | 72.95 N·m | required 54.3 N·m, torque margin 34% |
| Overload check (peak ×1.0 vs λ=2.0) | 54 / 146 N·m ✓ | Peak torque within overload capability |
| Estimated rated current I_N | 21.85 A | √3·U·η·cosφ (for contactor / thermal relay sizing) |
| matching drive capacity reference | ≥ 24 A VFD | select at 1.1–1.2× motor rated current |
| drive scheme suggestion | Induction motor + VFD; for wide-range low-speed running choose an inverter-duty motor (separate cooling) |
Engineering notes
- Four sizing steps: compute load power → apply the service factor → round to a standard power tier → check rated torque and peak overload.
- Select breakers / contactors / thermal relays by rated current; set the thermal relay to 1.05–1.1× I_N.
- DC machines don’t use power factor for current (I = P/(U·η)); size BLDC drives by bus current separately.
FAQ
- What is Motor Sizing (Load Torque) for?
- Size AC induction, DC, or brushed/brushless motors by load profile (constant torque / power / quadratic / shock): power, standard tier rounding, torque and overload check.
- What is the formula for Motor Sizing (Load Torque)?
- Core formula: P_L = T_L·n_L/9550 | P_N ≥ K·P_L/η_t | T_N = 9550·P_N/n_N | peak ≤ λ·T_N. The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using Motor Sizing (Load Torque)?
- Four sizing steps: compute load power → apply the service factor → round to a standard power tier → check rated torque and peak overload. Select breakers / contactors / thermal relays by rated current; set the thermal relay to 1.05–1.1× I_N. DC machines don’t use power factor for current (I = P/(U·η)); size BLDC drives by bus current separately.
Embed this calculator on your site / blog / intranet
Copy the snippet below into any HTML-capable page — visitors get the same live calculator, styling included.